ubuntu – lm-sensors电压报警,可以安全忽略?

我正在构建一个小型NAS服务器,主板是 Intel D2700MUD(无风扇),PSU是“Ace Outburst 480W”.安装Ubuntu Server后,我安装了lm-sensors.输出
coretemp-isa-0000
Adapter: ISA adapter
Core 0:       +38.0 C  (high = +80.0 C,crit = +100.0 C)
Core 1:       +33.0 C  (high = +80.0 C,crit = +100.0 C)

w83627dhg-isa-0290
Adapter: ISA adapter
Vcore:        +1.22 V  (min =  +0.00 V,max =  +1.74 V)
in1:          +1.02 V  (min =  +0.58 V,max =  +1.06 V)
AVCC:         +3.38 V  (min =  +2.78 V,max =  +0.64 V)  ALARM
+3.3V:        +3.38 V  (min =  +0.82 V,max =  +0.59 V)  ALARM
in4:          +1.03 V  (min =  +1.25 V,max =  +0.42 V)  ALARM
in5:          +1.52 V  (min =  +1.78 V,max =  +0.51 V)  ALARM
in6:          +1.02 V  (min =  +0.16 V,max =  +0.10 V)  ALARM
3VSB:         +3.34 V  (min =  +1.65 V,max =  +1.15 V)  ALARM
Vbat:         +3.22 V  (min =  +2.34 V,max =  +1.02 V)  ALARM
fan1:           0 RPM  (min = 2109 RPM,div = 128)  ALARM
fan2:           0 RPM  (min =  458 RPM,div = 128)  ALARM
fan3:           0 RPM  (min =  234 RPM,div = 128)  ALARM
fan4:           0 RPM  (min =  659 RPM,div = 128)  ALARM
fan5:           0 RPM  (min = 5273 RPM,div = 128)  ALARM
temp1:        +44.0 C  (high = +35.0 C,hyst = +32.0 C)  ALARM  sensor = diode
temp2:       +110.5 C  (high = +80.0 C,hyst = +75.0 C)  ALARM  sensor = diode
temp3:        +30.5 C  (high = +80.0 C,hyst = +75.0 C)  sensor = diode
cpu0_vid:    +2.050 V

我是否需要担心in4,in5,in6 ..或temp1 / temp2的电压警报?

限制未正确配置,它们可能是默认值或来自其他一些板.例如:

3.3V:3.38 V(最小值= 0.82 V,最大值= 0.59 V)

对于3.3V电源而言看起来合理,但限制完全没有,并且最大值低于最小值!

temp2看起来有点令人担忧,但这也可能是一个配置错误的传感器.

相关文章

1.安装过程出现0x00000000指令引用的0x00000000内存该内存不能为written 如果你安装的是inux系统 需要在...
写在全面:如果根据以下教程涉及到只读文件需要更改文件权限才能需修改文件内容,参考我的另一篇博客:...
写在前面:以下步骤中需要在终端输入命令,电脑端查看博客的朋友可以直接复制粘贴到终端,手机端查看的...
ubuntu16.04和18.04更换国内源 写在前面:安装好ubuntu双系统后,默认的软件更新源是国外的,在国内使用...
ubuntu双系统启动时卡死解决办法(在ubuntu16.04和18.04测试无误) 问题描述: 在安装完ubuntu双系统后...
又来造轮子了。。。。。。。。。。。。。。。。 今天使用w3af向文件中写入的时候,发现没有write权限,...