windows-server-2008 – 为什么我的域服务器(2008 R2)不能正确地与外部时间服务同步?

前端之家收集整理的这篇文章主要介绍了windows-server-2008 – 为什么我的域服务器(2008 R2)不能正确地与外部时间服务同步?前端之家小编觉得挺不错的,现在分享给大家,也给大家做个参考。
我已将PDC( Windows 2008 R2)配置为与外部时间源uk.pool.ntp.org同步,并按照此处列出的所有说明操作:

http://blogs.technet.com/b/industry_insiders/archive/2006/08/29/w32-tm-service.aspx

但由于某种原因,它总是比正确的时间快5-6分钟.当我查询对等体的值时,它显示

C:\Windows\system32>w32tm /query /peers
#Peers: 1

Peer: uk.pool.ntp.org,0x1
State: Active
Time Remaining: 732.9759988s
Mode: 1 (Symmetric Active)
Stratum: 2 (secondary reference - syncd by (S)NTP)
PeerPoll Interval: 10 (1024s)
HostPoll Interval: 10 (1024s)

C:\Windows\system32>w32tm /monitor /computers:uk.pool.ntp.org
uk.pool.ntp.org[82.219.4.30:123]:
    ICMP: 15ms delay
    NTP: -339.9182573s offset from local clock
        RefID: ntp2.linx.net [195.66.241.10]
        Stratum: 2

Warning:
Reverse name resolution is best effort. It may not be
correct since RefID field in time packets differs across
NTP implementations and may not be using IP addresses.

谁能告诉我为什么会这样?这让我很生气!!

提前致谢.

好的所以经过大量的查看,检查和重新配置,我有一个巨大的AH HAAH!时刻:

这台机器作为虚拟服务器运行!
Hyper-V具有时间同步集成服务.
检查时Hyper-V主机有错误的时间!

转到此域服务器的hyper-v管理器上的设置,并取消选中管理下的时间同步 – >整合服务然后申请,立即解决问题!

我真的希望这有助于某人.

原文链接:https://www.f2er.com/windows/368889.html

猜你在找的Windows相关文章